Factory Height
: 9m
Floor Design Loads
Ground Floor Production
1st Floor Production
2st Floor Office
: 20KN/m²(Non Suspended Floor Slab)
: 10KN/m²
: 2.5KN/m²
Roof System
Roof Structure
Roof Sheets
Rain Water Down Pipe
Gutter
: Structural Steel Designed to BS 5950 Standard
: Zincalume Metal Roof c/w 50mm Thick Fiberglass Insulation
: Exposed 150mm ∅ UPVC Pipe (Production Area)
Concealed 150mm ∅ UPVC Pipe (Office Area)
: Stainless Steel Gutter
Walls
Internal Wall
External Walls
: 115mm Thick Common Brick Wall with Plaster and
Painted with Emulsion Paint
: Ceramic Wall Tiles to Toilets and Pantry (2.1m Height)
: 115mm Thick Common Brick Wall with Plaster
and Painted with Weather Bond Paint
Floors
Ground floor
Production Finishes
Office & Lobby Finishes
Lobby Staircase Finishes
: 150mm Thick G25 concrete with a Layer of Polythene
Sheet and BRC A7
: 4kg/m² Floor Hardener Finishes
: Polish Tiles
: Homogeneous Tiles
Doors
External Doors
Internal Doors
: Motorized Roller Shutters and Mild Steel Doors
(Production Area)
: Timber Flush Door (Office Area)
Windows
External Windows
Ceiling
Office Area
Production Area
: 2ft x 4ft Gypsum Pin Hole False Ceiling
(Office Area)
: Exposed Structure (No Ceiling)
Infrastructure Works
External Road
Parking Bays
Fencing
Gate
Drainage System
Sewerage System
Ancillary Building
10 Person Passenger Lift (By 3 Stops)
2 Tones Goods Hoist (By 2 Stops)
Guard House
TNB Sub-station
Dock Leveller
: 150mm Thick Reinforced Concrete Road c/w
Road Marking
: 150mm Thick Reinforced Concrete Road c/w
Parking Lot
: Front Signage : 9m Lenght Common Brick Wall
with c/w Plaster and Painted with
Weatherbond Paint
: Perimeter : 2m High Pre-cast Wall or Common
Brick Wall
: 9m Wide Sliding Gate w/o Motor
: Concealed Pipe Culvert Drain
: Vitrified clay pipe (VCP) connect to main
sewerage line
: Bin Center
: 1 no.
: 1 no.
: 1 no.
: Subject to appropriate authority requirement
: 2 nos.
STANDARD MECHANICAL & ELECTRICAL SPECIFICATION
MSB 1000A (incoming 600A)
DB 100A
DB 60A
DB 30A
Lighting Point
13A S/S/O
Air-Cond Power Point
Emergency Light
Keluar Sign
Telephone Point
30A Isolator Point
: 1 no.
: 1 no.
: 3 nos.
: 1 no.
: 120 nos.
: 50 nos.
: 12 nos.
: 30 nos.
: 10 nos.
: 1 no
: 2 nos.
FIRE PROTECTION SYSTEMS
Fire Alarm System
Hosereel System
Portable Fire Extinguisher
Direct Link to Fire Bridgate
Hydrant System
: Yes
: Yes
: Yes
: Yes
: Yes
: Yes
Factory Height
9m
Floor Design Loads
Ground Floor Production
20KN/m², Non Suspended Floor Slab
1st Floor Production
10KN/m²
2nd Floor Office
2.5KN/m²
Roof Structure
Structural Steel Designed to BS 5950 Standard
Roof Sheets
Zincalume Metal Roof c/w 50mm Thick Fiberglass Insulation
Rain Water Down Pipe
Exposed 150mm ∅ UPVC, Pipe(Production Area), Concealed 150mm ∅ UPVC, Pipe(Office Area)
Gutter
Stainless Steel Gutter
Internal Wall
115mm Thick Common Brick Wall with Plaster and Painted with Emulsion Paint, Ceramic Wall Tiles to Toilets and Pantry (2.1m Height)
External Walls
115mm Thick Common Brick Wall with Plaster and Painted with Weather Bond Paint.
Floors
Ground Floor
150mm Thick G25 concrete with a Layer of Polythene Sheet and BRC A7
Production Finishes
4kg/m² Floor Hardener Finishes
Office & Lobby Finishes
Polish Tiles
Lobby Staircase Finished
Homogeneous Tiles
External Doors
Motorized Roller Shutters and Mild Steel Doors (Production Area), 12mm Tinted Tempered Glass Door (Entrance Area)
Internal Doors
Timber Flush Door (Office Area)
Windows
External Windows
NA Aluminium Sliding Windows (Production Area)
Reflective Glass Curtain Wall (Office Area)
Aluminium Framed Top Hung Windows (Office Area)
Ceiling
Office Area
2ft x 4ft Gypsum Pin Hole False Ceiling (Office Area)
Production Area
Exposed Structure (No Ceiling)
Infrastructure Works
External Road
150mm Thick Reinforced Concrete Road c/w Road Marking
Parking Bays
150mm Thick Reinforced Concrete Road c/w Parking Lot
Fencing
Front Signage : 9m Length, Common Brick Wall with c/w, Plaster and Painted with Weatherbond Paint
Perimeter: 2m High Pre-cast Wall or Common Brick Wall
Gate
9m Wide Sliding Gate w/o Motor
Drainage System
Concealed Pipe Culvert Drain
Sewerage System
Vitrified Clay Pipe (VCP) Connect to Main Sewerage Line
Ancillary Building
Bin Center
10 Person Passenger Lift (By 3 Stops)
1 No.
2 Tones Goods Hoist (By 2 Stops)
1 No.
Guard House
1 No.
TNB Sub-station
Subject to Appropriate Authority Requirement
Dock Leveller
2 No.
STANDARD MECHANICAL & ELECTRICAL SPECIFICATION
MSB 1000A (incoming 600A)
1 No.
DB 100A
1 No.
DB 60A
3 Nos.
DB 30A
1 No.
Lighting Point
120 Nos.
13A S/S/O
50 Nos.
Air-Cond Power Point
12 Nos.
Emergency Light
30 Nos.
Keluar’ Sign
10 Nos.
Telephone Point
1 No.
30A Isolator Point
2 Nos.
FIRE PROTECTION SYSTEMS
Fire Alarm System
Yes
Hosereel System
Yes
Automatic Sprinkler System
(Ordinary Hazard)
Yes
Portable Fire Extinguisher
Yes
Direct Link to Fire Bridgate
Yes
Hydrant System
Yes
PHONE / HELPLINE
FAX
AME DEVELOPMENT SDN BHD 200801002418 (803702-H)