Factory Height
: 9m
Floor Design Loads
Production area (Ground Floor)
Office Area (Mezzanine Floor)
: 20KN/m²(Non Suspended Floor Slab)
: 2.5KN/m²
Roof Design Loads
Production Area Roof
: Imposed dead load = 0.25kN/m² (Load of Rafter,
Purlin, Metal Roofing Sheet, Insulation, Lighting
Fitting, Sprinkler Pipe)
Live load= 0.25kN/m²
Roof System
Roof Structure
Roof Sheets
Gutter
: Structural Steel Designed to BS 5950 Standard
: Metal Roof or equivalent c/w
insulation
: Stainless Steel Gutter
Walls
Internal Wall
(Office and Sprinkler Tank Area)
External Wall (Office Area)
External Wall (Production Area)
: 115mm thick common brick wall with plaster and
painted with emulsion paint
Matt finishes tiles to toilets (2.9m)
: 115mm thick common brick wall with plaster and
painted with weather resistant paint
: 2.1m high wall with metal cladding and translucent sheet above
Floors
Ground floor
Production Finishes
Lobby & Lobby Staircase Finishes
Office Finishes
Toilet Floor Finishes
: 150mm G30 concrete with a layer of
polythene sheet and BRC A7 or steel fibre
: 4kg/m² floor harderner finishes
: Matt finishes tiles or equivalent standard
: Cement Render
: Matt finishes tiles
Doors
External Doors
Internal Doors
: Motorized Roller Shutters and Mild Steel Doors
(Production Area)
: Tempered Glass Door (Entrance Area)
: Fire-rated Door (Based on local authority
requirement) & Timber Flush Door (Office Area)
Windows
External Windows
: Aluminium Frame Top Hung and Fixed Glass Window (Production Area)
: Reflective Glass Curtain Wall (Office Area)
: Aluminium Framed Top Hung Windows (Office Area)
Ceiling
Office Area
Production Area
: Gypsum Pin Hole False Ceiling
(Office Area)
: Gypsum Board Plaster Ceiling(Lobby Area)
: Exposed Steel Structure (No Ceiling)
Infrastructure & Amenities
External Road
Drainage System
Sewerage System
Refuse Room
Recycle Room
Guard House
Sprinkler Tank & Plinth
TNB Sub-station
Dock Leveller
: Sliding Gate Without Motor
: Power Point for Motor Provided
: Concealed Pipe Culvert Drain
: Vitrified clay pipe (VCP) connect to main
sewerage line
: 1 no.
: 1 no.
: 1 no.
: Yes
: Subject to appropriate authority requirement
: 4 nos.
STANDARD MECHANICAL & ELECTRICAL SPECIFICATION
MSB 1250A
DB 150A
DB 80A
DB 60A
DB 30A
Lighting Point
13A S/S/O
15A Air-Cond Power Point
Emergency Light
Keluar Sign
Telephone Point
Data Point
30A Isolator Point
: Setting 1000A
: Yes
: Yes
: Yes
: Yes
: Yes
: Yes
: Yes
: Subject to appropriate authority requirement
: Subject to appropriate authority requirement
: Yes
: Yes
: Yes
FIRE PROTECTION SYSTEMS
Fire Alarm System
Hosereel System
Portable Fire Extinguisher
Direct Link to Fire Bridgate
Hydrant System
: Yes
: Yes
: Yes
: Yes
: Yes
: Yes
PLUMBING & WATER RECTICULATION SYSTEMS
Water Tank for Toilet only
Incoming Domestic Piping & Discharged Piping
: Yes
: Yes
Factory Height
9m
Floor Design Loads
Production area (Ground Floor)
20KN/m², Non Suspended Floor Slab
Office Area (Mezzanine Floor)
2.5KN/m²
Roof Design Loads
Roof Structure
Structural Steel Designed to BS 5950 Standard
Gutter
Stainless Steel Gutter
Internal Wall (Office and Sprinkler Tank Area)
115mm thick common brick wall with plaster and painted with emulsion paint
Matt finishes tiles to toilets (2.9m high)
Floors
Production Finishes
4kg/m² Floor Hardener Finishes
Office Finished
Cement Render
Toilet Floor Finishes
Matt finishes tiles
External Doors
Motorized Roller Shutters and Mild Steel Doors (Production Area)
Internal Doors
Fire-rated Door (Based on local authority requirement) & Timber Flush Door (Office Area)
Windows
External Windows
Aluminium Frame Top Hung and Fixed Glass Window (Production Area)
Reflective Glass Curtain Wall (Office Area)
Aluminium Framed Top Hung Windows (Office Area)
Ceiling
Office Area
Gypsum Pin Hole False Ceiling (Office Area), Gypsum Board Plaster Ceiling (Lobby Area)
Production Area
Exposed Steel Structure (No Ceiling)
Infrastructure & Amenities
External Road
Reinforced Concrete Road c/w road marking
Fencing
Front Signage : Common Brick Wall with c/w plaster cement and painted with weather resistant paint
Perimeter: 250mm Low Wall with 1800mm High BSP Fencing
Gate
Sliding Gate Without Motor, Power Point for Motor Provided
Drainage System
Concealed Pipe Culvert Drain
Sewerage System
Vitrified clay pipe (VCP) connect to main sewerage line
Refuse Room
1 no.
Recycle Room
1 no.
Guard House
1 no.
Sprinkler Tank & Plinth
Yes
TNB Sub-station
Subject to appropriate authority requirement
Dock Leveller
4 nos.
Standard Mechanical & Electrical Specification
MSB 1250A
Setting 1000A
DB 150A
Yes
DB 80A
Yes
DB 60A
Yes
DB 30A
Yes
Lighting Point
Yes
13A S/S/O
Yes
15A Air-Cond Power Point
Yes
Emergency Light
Subject to appropriate authority requirement
Keluar’ Sign
Subject to appropriate authority requirement
Telephone Point
Yes
Data Point
Yes
30A Isolator Point
Yes
Fire Protection Systems
Fire Alarm System
Yes
Hosereel System
Yes
Automatic Sprinkler System (Ordinary Hazard)
Yes
Portable Fire Extinguisher
Yes
Direct Link to Fire Bridgate
Yes
Hydrant System
Yes
Plumbing & Water Recticulation Systems
Water Tank for Toilet only
Yes
Incoming Domestic Piping & Discharged Piping
Yes